mirror of
https://github.com/inventree/InvenTree.git
synced 2025-06-14 11:05:41 +00:00
* Add shell task * Filter parts by parameter value * Allow more operation types * Working on table filtering * Filter improvements * Update on enter key * Improved query logic * Enable filter for "generic" parameter types * Placeholder text * Documentation updates * Fix typo * Fix for boolean part parameter field * Add API unit testings * Cleanup * add playwright tests
131 lines
6.3 KiB
Markdown
131 lines
6.3 KiB
Markdown
---
|
|
title: Part Parameters
|
|
---
|
|
|
|
## Part Parameters
|
|
|
|
A part *parameter* describes a particular "attribute" or "property" of a specific part.
|
|
|
|
Part parameters are located in the "Parameters" tab, on each part detail page.
|
|
There is no limit for the number of part parameters and they are fully customizable through the use of [parameter templates](#parameter-templates).
|
|
|
|
Here is an example of parameters for a capacitor:
|
|
|
|
{{ image("part/part_parameters_example.png", "Part Parameters Example") }}
|
|
|
|
## Parameter Templates
|
|
|
|
Parameter templates are used to define the different types of parameters which are available for use. The following attributes are defined for a parameter template:
|
|
|
|
| Attribute | Description |
|
|
| --- | --- |
|
|
| Name | The name of the parameter template (*must be unique*) |
|
|
| Description | Optional description for the template |
|
|
| Units | Optional units field (*must be a valid [physical unit](#parameter-units)*) |
|
|
| Choices | A comma-separated list of valid choices for parameter values linked to this template. |
|
|
| Checkbox | If set, parameters linked to this template can only be assigned values *true* or *false* |
|
|
| Selection List | If set, parameters linked to this template can only be assigned values from the linked [selection list](#selection-lists) |
|
|
|
|
### Create Template
|
|
|
|
Parameter templates are created and edited via the [settings interface](../settings/global.md).
|
|
|
|
To create a template:
|
|
|
|
- Navigate to the "Settings" page
|
|
- Click on the "Part Parameters" tab
|
|
- Click on the "New Parameter" button
|
|
- Fill out the `Create Part Parameter Template` form: `Name` (required) and `Units` (optional) fields
|
|
- Click on the "Submit" button.
|
|
|
|
An existing template can be edited by clicking on the "Edit" button associated with that template:
|
|
|
|
{{ image("part/parameter_template_edit.png", "Edit Parameter Template") }}
|
|
|
|
### Create Parameter
|
|
|
|
After [creating a template](#create-template) or using the existing templates, you can add parameters to any part.
|
|
|
|
To add a parameter, navigate to a specific part detail page, click on the "Parameters" tab then click on the "New Parameters" button, the `Create Part Parameter` form will be displayed:
|
|
|
|
{{ image("part/create_part_parameter.png", "Create Part Parameter Form") }}
|
|
|
|
Select the parameter `Template` you would like to use for this parameter, fill-out the `Data` field (value of this specific parameter) and click the "Submit" button.
|
|
|
|
## Parametric Tables
|
|
|
|
Parametric tables gather all parameters from all parts inside a particular [part category](./index.md#part-category) to be sorted and filtered.
|
|
|
|
To access a category's parametric table, click on the "Parameters" tab within the category view:
|
|
|
|
{{ image("part/parametric_table_tab.png", "Parametric Table Tab") }}
|
|
|
|
### Sorting by Parameter Value
|
|
|
|
The parametric parts table allows the returned parts to be sorted by particular parameter values. Click on the header of a particular parameter column to sort results by that parameter:
|
|
|
|
{{ image("part/part_sort_by_param.png", "Sort by Parameter") }}
|
|
|
|
### Filtering by Parameter Value
|
|
|
|
The parametric parts table allows the returned parts to be filtered by particular parameter values. Click on the {{ icon("filter") }} button associated with the particular parameter, and enter the value you wish to filter against:
|
|
|
|
{{ image("part/filter_by_param.png", "Filter by Parameter") }}
|
|
|
|
The available filter options depend on the type of parameter being filtered. For example, a parameter with a limited set of choices will allow you to filter by those choices, while a numeric parameter will allow you to filter against a specific value and operator (e.g. greater than, less than, etc.).
|
|
|
|
#### Filtering by Multiple Parameters
|
|
|
|
Multiple parameters can be used to filter the parametric table. Simply add a new filter for each parameter you wish to filter against. The results will be filtered to include only parts which match *all* of the specified filters.
|
|
|
|
Each parameter column indicates whether a filter is currently applied:
|
|
|
|
{{ image("part/multiple_param_filters.png", "Multiple Parameter Filters") }}
|
|
|
|
#### Unit-Aware Filtering
|
|
|
|
When filtering against a parameter which has a unit defined, you can specify the value in any compatible unit. The system will automatically convert the value to the base unit defined for that parameter template.
|
|
|
|
For example, to show all parts with a *Resistance* parameter of greater than 10kΩ, you can enter `10k` or `10000` in the filter field, and the system will correctly interpret this as 10,000 ohms.
|
|
|
|
{{ image("part/filter_with_unit.png", "Unit Aware Filters") }}
|
|
|
|
#### Remove Filter
|
|
|
|
To remove a filter against a given parameter, click on the {{ icon("circle-x", color='red') }} button associated with that filter:
|
|
|
|
{{ image("part/remove_param_filter.png", "Remove Parameter Filter") }}
|
|
|
|
|
|
## Parameter Units
|
|
|
|
The *units* field (which is defined against a [parameter template](#parameter-templates)) defines the base unit of that template. Any parameters which are created against that unit *must* be specified in compatible units.
|
|
|
|
The in-built conversion functionality means that parameter values can be input in different dimensions - *as long as the dimension is compatible with the base template units*.
|
|
|
|
!!! info "Read Mode"
|
|
Read more about how InvenTree supports [physical units of measure](../concepts/units.md)
|
|
|
|
### Incompatible Units
|
|
|
|
If a part parameter is created with a value which is incompatible with the units specified for the template, it will be rejected:
|
|
|
|
{{ image("part/part_invalid_units.png", "Invalid Parameter Units") }}
|
|
|
|
This behaviour can be disabled if required, so that any parameter value is accepted.
|
|
|
|
### Parameter Unit Sorting
|
|
|
|
Parameter sorting takes unit conversion into account, meaning that values provided in different (but compatible) units are sorted correctly:
|
|
|
|
{{ image("part/part_sorting_units.png", "Sort by Parameter Units") }}
|
|
|
|
### Selection Lists
|
|
|
|
Selection Lists can be used to add a large number of predefined values to a parameter template. This can be useful for parameters which must be selected from a large predefined list of values (e.g. a list of standardised colo codes). Choices on templates are limited to 5000 characters, selection lists can be used to overcome this limitation.
|
|
|
|
It is possible that plugins lock selection lists to ensure a known state.
|
|
|
|
|
|
Administration of lists can be done through the Part Parameter section in the [Admin Center](../settings/admin.md#admin-center) or via the API.
|