* adds new field 'parameter type' to PartParameterTemplate model * Move part parameter settings onto their own page * Add "choices" and "regex" template types * Adds validation for PartParameter based on template type * javascript cleanup * Fix for serializers.py * Add unit testing for parameter validation * Add filters * Rename "type" field to "param_type" - Should have seen that one coming * Coerce 'boolean' value to True/False * table update * js linting * Add requirement for "pint" package * Add validator for physical unit types - Revert a previous migration which adds "parameter type" and "validator" fields - These will get implemented later, too much scope creep for this PR - Add unit test for validation of "units" field * Update PartParameter model - Add data_numeric field (will be used later) - Add MinLengthValidator to data field * Run validation for part parameter data - Ensure it can be converted to internal units * Update admin interface to display partparameter values inline for a part * Adds validation of part parameter data value - Also converts to base units, and stores as "numeric" value - Display "numeric" value in tables - Create new file conversion.py for data conversion * Update unit tests and fix some bugs * Update docstring * Add units to parameter columns in parameteric part table * Allow part list to be ordered by a particular parameter value - Annotate queryset with new "order_by_parameter" method - Skeleton method for future work * Bump API version * Adds unit testing for sorting parts by parameter value * Update historical data migrations - Turns out RunPython.noop is a thing? * Cache the unit registry - Creating the unit registry takes a significant amount of time - Construct when first called, and then cache for subsequent hits - Massive improvement in performance * Throw error on empty values when converting between units * Data migration for converting existing part parameter values * Handle more error cases * Show parameteric table on top-level part page too * Unit test for data migration * Update credits in docs * Improved error checking * WIP docs updates * Fix parameteric table filtering * remove zoom property * Fix for import path * Update parameter docs * Run background task to rebuild parameters when template changes * Make "data_numeric" field nullable - Defaulting to zero is not appropriate, as the actual value may be zero - Sorting still seems to work just fine * Fixes for unit test * More unit test fixes * Further fixes for unit tests --------- Co-authored-by: Matthias Mair <code@mjmair.com>
92 lines
4.0 KiB
Markdown
92 lines
4.0 KiB
Markdown
---
|
|
title: Part Parameters
|
|
---
|
|
|
|
## Part Parameters
|
|
|
|
A part *parameter* describes a particular "attribute" or "property" of a specific part.
|
|
|
|
Part parameters are located in the "Parameters" tab, on each part detail page.
|
|
There is no limit for the number of part parameters and they are fully customizable through the use of [parameters templates](#parameter-templates).
|
|
|
|
Here is an example of parameters for a capacitor:
|
|
{% with id="part_parameters_example", url="part/part_parameters_example.png", description="Part Parameters Example List" %}
|
|
{% include 'img.html' %}
|
|
{% endwith %}
|
|
|
|
## Parameter Templates
|
|
|
|
Parameter templates are used to define the different types of parameters which are available for use. These are edited via the [settings interface](../settings/global.md).
|
|
|
|
### Create Template
|
|
|
|
To create a template:
|
|
|
|
- Navigate to the "Settings" page
|
|
- Click on the "Parts" tab
|
|
- Scroll down to the "Part Parameter Templates" section
|
|
- Click on the "New Parameter" button
|
|
- Fill out the `Create Part Parameter Template` form: `Name` (required) and `Units` (optional) fields
|
|
- Click on the "Submit" button.
|
|
|
|
### Create Parameter
|
|
|
|
After [creating a template](#create-template) or using the existing templates, you can add parameters to any part.
|
|
|
|
To add a parameter, navigate to a specific part detail page, click on the "Parameters" tab then click on the "New Parameters" button, the `Create Part Parameter` form will be displayed:
|
|
|
|
{% with id="create_part_parameter", url="part/create_part_parameter.png", description="Create Part Parameter Form" %}
|
|
{% include 'img.html' %}
|
|
{% endwith %}
|
|
|
|
Select the parameter `Template` you would like to use for this parameter, fill-out the `Data` field (value of this specific parameter) and click the "Submit" button.
|
|
|
|
## Parametric Tables
|
|
|
|
Parametric tables gather all parameters from all parts inside a particular [part category](./part.md#part-category) to be sorted and filtered.
|
|
|
|
To access a category's parametric table, click on the "Parameters" tab within the category view:
|
|
|
|
{% with id="parametric_table_tab", url="part/parametric_table_tab.png", description="Parametric Table Tab" %}
|
|
{% include 'img.html' %}
|
|
{% endwith %}
|
|
|
|
Below is an example of capacitor parametric table filtered with `Package Type = 0402`:
|
|
|
|
{% with id="parametric_table_example", url="part/parametric_table_example.png", description="Parametric Table Example" %}
|
|
{% include 'img.html' %}
|
|
{% endwith %}
|
|
|
|
### Sorting by Parameter Value
|
|
|
|
The parametric parts table allows the returned parts to be sorted by particular parameter values. Click on the header of a particular parameter column to sort results by that parameter:
|
|
|
|
{% with id="sort_by_param", url="part/part_sort_by_param.png", description="Sort by Parameter" %}
|
|
{% include 'img.html' %}
|
|
{% endwith %}
|
|
|
|
## Parameter Units
|
|
|
|
The *units* field (which is defined against a [parameter template](#parameter-templates)) defines the base unit of that template. Any parameters which are created against that unit *must* be specified in compatible units. Unit conversion is implemented using the [pint](https://pint.readthedocs.io/en/stable/) Python library. This conversion library is used to perform two main functions:
|
|
|
|
- Enforce use of compatible units when creating part parameters
|
|
- Perform conversion to the base template unit
|
|
|
|
The in-built conversion functionality means that parameter values can be input in different dimensions - *as long as the dimension is compatible with the base template units*.
|
|
|
|
### Incompatible Units
|
|
|
|
If a part parameter is created with a value which is incompatible with the units specified for the template, it will be rejected:
|
|
|
|
{% with id="invalid_units", url="part/part_invalid_units.png", description="Invalid Parameter Units" %}
|
|
{% include 'img.html' %}
|
|
{% endwith %}
|
|
|
|
### Parameter Sorting
|
|
|
|
Parameter sorting takes unit conversion into account, meaning that values provided in different (but compatible) units are sorted correctly:
|
|
|
|
{% with id="sort_by_param_units", url="part/part_sorting_units.png", description="Sort by Parameter Units" %}
|
|
{% include 'img.html' %}
|
|
{% endwith %}
|